4 Va. Admin. Code § 25-101-170

Current through Register Vol. 41, No. 3, September 23, 2024
Section 4VAC25-101-170 - Pillars of coal to be left unmined, and other protective measures
A. When mining using an underground, auger or highwall mining method within 200 horizontal feet of a vertical ventilation hole or a gas well, the mine operator shall submit a plan showing the projected pillars of coal to be left unmined around each hole or well.
B. Pillars shall be situated so that each hole or well is centered within a pillar, and each pillar shall conform to the specifications shown in Table I below, based on the depth of cover above the area being mined. The entries developed adjacent to any pillar may not exceed 20 feet in width without prior approval from the chief. In no circumstances may the most narrow pillar dimension be less than twice the width of the adjacent entries.

Table I Pillar Specifications
Cover (in feet) Required Solid Pillar Area (in square feet) Required Additional Pillar Area (Solid or Split, in sq. ft.) Total Area Bearing Surface Required (in sq. ft.)
0-149 3,600 3,600
150-249 5,625 5,625
250-349 10,000 10,000
350-449 10,000 5,600 15,600
450-549 10,000 13,000 23,000
550-649 10,000 22,000 32,000
650 or more 10,000 30,000 40,000

4 Va. Admin. Code § 25-101-170

Derived from Virginia Register Volume 17, Issue 20, eff. July 18, 2001.

Statutory Authority

§§ 45.1-161.3, 45.1-161.106, 45.1-161.121, 45.1-161.254 and 45.1-161.292 of the Code of Virginia.