Okla. Admin. Code § 785:25-3-7

Current through Vol. 42, No. 3, October 15, 2024
Section 785:25-3-7 - Minimum valley floor drain capacities
(a)Requirements for valley floor drain capacity shall be as follows:
(1) All dams subject to the Board's jurisdiction shall have at least one valley floor drain of sufficient capacity to prevent interference with natural streamflow and injury of downstream appropriators and domestic users. Absent evidence to the contrary, the minimum size of the valley floor drains shall be as set forth in subsection (d) of this section.
(2) The height of the valley floor drain shall be no more than five feet (5') above the natural stream channel unless otherwise ordered by the Board. The capacity of the reservoir below the valley floor drain shall be designated as the inactive pool.
(b)Valley floor drain operation. All valley floor drains shall be gate- or valve-operated on the upstream side and shall be maintained in an operable condition at all times.
(c)Valley floor drain design life. The design life expectancy of the conduit shall be equal to or greater than the design life of the dam.
(d)Minimum size valley floor drain requirements. The valley floor drain must be of sufficient size to draw down the entire reservoir to the inactive pool within twenty (20) days, provided that minimum size outlet requirements are as follows:
(1) For less than 100 acre-feet normal pool capacity (at principal spillway), the minimum size of valley floor drain is 6-inch pipe.
(2) For 101 to 150 acre-feet normal pool capacity (at principal spillway), the minimum size of valley floor drain is 8-inch pipe.
(3) For 151 to 200 acre-feet normal pool capacity (at principal spillway), the minimum size of valley floor drain is 10-inch pipe.
(4) For 201-250 acre-feet normal pool capacity (at principal spillway), the minimum size of valley floor drain is 12-inch pipe.
(5) For 251-300 acre-feet normal pool capacity (at principal spillway), the minimum size of valley floor drain is 14-inch pipe.
(6) For 301-350 acre-feet normal pool capacity (at principal spillway), the minimum size of valley floor drain is 15-inch pipe.
(7) For 351-500 acre-feet normal pool capacity (at principal spillway), the minimum size of valley floor drain is 16-inch pipe.
(8) For more than 500 acre-feet normal pool capacity (at principal spillway), the minimum size of valley floor drain is 24-inch pipe.
(e)Amendments of minimum requirements for good cause. Minimum size requirements may be amended by the Board for good cause. However, the valley floor drain must be of sufficient size to draw down the entire reservoir to the inactive pool within a period of not more than twenty (20) days.

Okla. Admin. Code § 785:25-3-7

Added at 21 Ok Reg 2625, eff 7-1-04
Amended by Oklahoma Register, Volume 41, Issue 22, August 1, 2024, eff. 8/11/2024