Okla. Admin. Code § 785:25-3-11

Current through Vol. 42, No. 3, October 15, 2024
Section 785:25-3-11 - Minimum safety factors

As a guide for use by the Board and by engineers designing new dams, assessing the condition of existing dams or proposing modifications to existing dams, the following safety factors shall be utilized for:

(1) Embankment dams:

LOADING CONDITIONMINIMUM FACTOR OF SAFETY*
Steady seepage at emergency spillway crest1.5
Rapid drawdown from principal spillway1.2
Earthquake - reservoir at emergency spillway crest for downstream slope; reservoir at principal spillway for upstream slope1.0
*The minimum factor of safety is calculated by the ratio of available shear strength to shear stress required for stable equilibrium.

(2) Concrete dams or concrete portions thereof:

LOADING CONDITIONMINIMUM FACTOR OF SAFETY** (by hazard classification of dam)
High and SignificantLow
Principal spillway level2.252.0
Inflow design flood at maximum pool level1.751.25
Principal spillway level with earthquakegreater than 1.0greater than 1.0
**These minimum factors of safety apply to the calculation of stress and the shear friction factor of safety within the structure of the rock/concrete interface and foundation.

Okla. Admin. Code § 785:25-3-11

Amended at 11 Ok Reg 2931, eff 6-13-94