Ohio Admin. Code 3701-33-08

Current through all regulations passed and filed through October 28, 2024
Section 3701-33-08 - Laundry facilities
(A) To comply with minimum standards of habitability:
(1) Laundry facilities for the use of all occupants shall be provided with the following:
(a) A supply of hot and cold running water;
(b) A roof over the laundry area;
(c) Floors constructed of impervious materials and sloped to a floor drain;
(d) Laundry tubs in the ratio of one per twenty-five occupants. Mechanical washers may be provided in lieu of laundry tubs, in the ratio of one per fifty occupants. Although, a minimum of one laundry tub shall be provided in addition to the mechanical washers; and
(e) Facilities for drying clothes.
(2) In camps constructed or substantially altered after April 2, 1985, laundry facilities shall be located in a building with a floor that is constructed of impervious materials and sloped to a floor drain.
(B) To comply with the voluntary standards of habitability:
(1) Mechanical washers shall be provided in the ratio of one per twenty five occupants; and
(2) Laundry facilities shall be located in a building with a floor that is constructed of impervious materials and is sloped to a floor drain.

Replaces: 3701-33-12

Ohio Admin. Code 3701-33-08

Effective: 1/1/2017
Five Year Review (FYR) Dates: 01/01/2022
Promulgated Under: 119.03
Statutory Authority: 3733.42
Rule Amplifies: 3733.42, 3733.43, 3733.431, 3733.44, 3733.45, 3733.46, 3733.47, 3733.471, 3733.48
Prior Effective Dates: 6/1/1975, 4/2/85, 9/6/98