Soil | Percolation | Required | Required |
---|---|---|---|
Permeability | Rate | Dose Volume | Dose Volume |
(in/hr) | (min/in) | Gravity Dosing | Pressure Dosing |
6-20 | 3-15 | minimum of 75 percent | minimum of 10V<2> |
V<1> | |||
maximum of 25 percent Q | maximum of 25 percent | ||
Q | |||
0.2-6 | 15-60 | minimum of 75 percent V | minimum of 10V |
maximum of 100 percent Q | maximum of 100 percent | ||
Q |
[LESS THAN]1[GREATER THAN] In cases where 75 percent V is larger than 25 percent Q, the 25 percent Q maximum rather than the percent minimum shall be observed.
[LESS THAN]2[GREATER THAN] In cases where 10V is larger than 25 percent Q, the 25 percent Q maximum rather than the 10V minimum shall be observed.
d, in = (V[d] + V[cp] + V[pd]) x (1 ft[LESS THAN]3[GREATER THAN]/7.48 gal) x (12 in/1 ft)/(A)
where:
V[d] is the required dose volume, in gallons, determined as prescribed in 7:9A-9.2(a)2;
V[cp] is the internal volume of all pipes which will drain back into the dosing tank at the end of a dosing cycle, in gallons;
V[pd] is the displacement, in gallons, of pump and controls; and
A is the internal horizontal area of the dosing tank, in square feet.
N.J. Admin. Code § 7:9A-9.2
See: 24 N.J.R. 1987(a), 25 N.J.R. 2704(b).
Amended by R.1999 d.314, effective 9/20/1999.
See: 31 N.J.R. 1416(a), 31 N.J.R. 2741(a).
In (b), inserted symbols throughout; and in (f)7ii, changed N.J.A.C. reference.
Amended by R.2012 d.066, effective 4/2/2012.
See: 43 N.J.R. 478(a), 44 N.J.R. 1047(a).
In (d)8, updated the N.J.A.C. reference; in (f)7iv, inserted "splices, junction boxes,"; and in (f)7v, inserted "to or", deleted "home or facility to the" preceding "pump", and substituted "installed in" for "protected by".