Authority: IC 13-14-8; IC 13-14-9; IC 13-15-1-2; IC 13-15-2-1; IC 13-18-3
Affected: IC 13-11-2; IC 13-18-4-7; IC 13-18-4-8
Sec. 11.4.
Also, any part of an assessment and remediation plan that also satisfies one (1) or more requirements under Section 303(d) of the CWA or implementing regulations may be incorporated by reference into a TMDL as appropriate. Assessment and remediation plans under this section shall be tailored to the level of detail and magnitude for the watershed and pollutant being assessed.
Where: | C | = | The adjusted TMDL, WLA calculated in the absence of a TMDL, or preliminary WLA concentration of each separate carcinogen that shall be used in the calculation of reasonable potential in section 11.5 of this rule and water quality-based effluent limitations (WQBELs) in section 11.6 of this rule. |
WLA | = | The TMDL, WLA calculated in the absence of a TMDL, or preliminary WLA concentration based on the HCC or HCV for each respective carcinogen. | |
n | = | Number of WLAs based on an HCC or HCV. |
Where: | N | = | The adjusted TMDL, WLA calculated in the absence of a TMDL, or preliminary WLA concentration of each separate additive noncarcinogenic substance that shall be used in the calculation of reasonable potential in section 11.5 of this rule and WQBELs in section 11.6 of this rule. |
WLA | = | The TMDL, WLA calculated in the absence of a TMDL, or preliminary WLA concentration based on the HNC or HNV for each respective additive noncarcinogenic substance. | |
n | = | Number of WLAs based on an HNC or HNV for additive noncarcinogenic substances. |
Where: | (TEC)tcdd | = | 2,3,7,8-TCDD toxicity equivalence concentration in effluent. |
(C)x | = | Concentration of total chemical x in effluent. | |
(TEF)x | = | TCDD toxicity equivalency factor for x. | |
(BEF)x | = | TCDD bioaccumulation equivalency factor for x. |
Table 11.4-1 | ||
Toxicity Equivalency Factors (TEF) and Bioaccumulation Equivalency Factors (BEF) for CDDs and CDFs | ||
Congener | TEF | BEF |
2,3,7,8-TCDD | 1.0 | 1.0 |
1,2,3,7,8-PeCDD | 0.5 | 0.9 |
1,2,3,4,7,8-HxCDD | 0.1 | 0.3 |
1,2,3,6,7,8-HxCDD | 0.1 | 0.1 |
1,2,3,7,8,9-HxCDD | 0.1 | 0.1 |
1,2,3,4,6,7,8-HpCDD | 0.01 | 0.05 |
OCDD | 0.001 | 0.01 |
2,3,7,8-TCDF | 0.1 | 0.8 |
1,2,3,7,8-PeCDF | 0.05 | 0.2 |
2,3,4,7,8-PeCDF | 0.5 | 1.6 |
1,2,3,4,7,8-HxCDF | 0.1 | 0.08 |
1,2,3,6,7,8-HxCDF | 0.1 | 0.2 |
2,3,4,6,7,8-HxCDF | 0.1 | 0.7 |
1,2,3,7,8,9-HxCDF | 0.1 | 0.6 |
1,2,3,4,6,7,8-HpCDF | 0.01 | 0.01 |
1,2,3,4,7,8,9-HpCDF | 0.01 | 0.4 |
OCDF | 0.001 | 0.02 |
Monitoring data for these LAs shall be collected and analyzed in order to validate the TMDL's assumptions, to verify anticipated load reductions, to evaluate the effectiveness of controls being used to implement the TMDL, and to revise the WLAs and LAs as necessary to ensure that water quality criteria shall be achieved within the time period established in the TMDL.
based upon a determination of adverse human health, aquatic life, or wildlife effects. The commissioner shall identify and document the rationale for this decision.
(A) | WQCc | = | The chronic water quality criterion or value. A chronic water quality criterion or value is any of the following: |
(i) CCC or SCC. If the CCC or SCC for a metal is expressed in the form of dissolved metal, the CCC or SCC shall be set equal to Cinstream determined for the CCC or SCC in accordance with subdivision (6). | |||
(ii) The numeric interpretation of the narrative chronic WET criterion (one and zero-tenths (1.0) TUc). | |||
(iii) HNC or HNV. | |||
(iv) HCC or HCV. | |||
(v) WC or WV. | |||
(vi) The criterion for chloride, sulfate, total dissolved solids, fluoride, or dissolved iron under 327 IAC 2-1.5-8(j). | |||
(B) | WQCa | = | The CMC or SMC or, if a mixing zone demonstration for acute WET is conducted and approved under subsection (b)(4), three-tenths (0.3) TUa for WET. If the CMC or SMC for a metal is expressed in the form of dissolved metal, the CMC or SMC shall be set equal to Cinstream determined for the CMC or SMC in accordance with subdivision (8). |
(C) | FAV | = | Two (2) times the CMC or SMC. If the CMC or SMC for a metal is expressed in the form of dissolved metal, the FAV shall equal two (2) times Cinstream determined for the CMC or SMC in accordance with subdivision (8). |
(D) | Qe | = | The facility effluent flow as determined by subsection (a)(9). |
(E) | Qw | = | The portion of the receiving waterbody allocated for mixing under subsection (b). If Cb is greater than the water quality criterion or value, a value of zero (0) shall be used for Qw. |
(F) | Cb | = | The representative background concentration determined by subsection (a)(8). |
(G) | DF | = | Dilution factor = Click to view image |
(H) | Qz | = | The portion of the receiving waterbody allocated for mixing in the zone of initial dilution. For discharges into tributaries that exhibit appreciable flows relative to their volumes, Qz = Qe or the Q1,10, whichever is less. For discharges into the open waters of Lake Michigan, Qz = Qe. If Cb is greater than WQCa, a value of zero (0) shall be used for Qz. |
WLA = WQCc
WLA = (WQCc)(DF) - (Cb)(DF-1)
WLA = WQCa
WLA = WQCc
Table 11.4-2 | ||
Metals Translators | ||
Dissolved to Total Recoverable | ||
Acute | Chronic | |
Substances | Translators | Translators |
Arsenic (III) | 1.000 | 1.000 |
Cadmium | 1.136672-[(ln hardness)(0.041838)] | 1.101672-[(ln hardness)(0.041838)] |
Chromium (III) | 0.316 | 0.860 |
Copper | 0.960 | 0.960 |
Mercury | 0.85 | 0.85 |
Nickel | 0.998 | 0.997 |
Selenium | 0.922 | 0.922 |
Zinc | 0.978 | 0.986 |
327 IAC 5-2-11.4