7 C.F.R. § 1924 app Exhibit B to Subpart C of Part 1924

Current through October 31, 2024
Appendix Exhibit B to Subpart C of Part 1924 - Site Development Design Requirements

This exhibit prescribes site development requirements to be used in developing residential sites in all housing programs. These requirements cover only those areas which involve health and safety concerns. They are not intended to cover all aspects of site development. Applicants and developers are expected to follow local practice, as a minimum, in all areas of site development not addressed in this exhibit. When State, local, or other requirements are applicable in addition to FmHA or its successor agency under Public Law 103-354 's requirements, the most stringent requirement shall apply.

Proper integration of the natural features of a site with the manmade improvements is one of the most critical aspects of residential development. Poor site planning in large scale subdivisions, rental projects and individual sites, has resulted in a loss of valuable private and public natural resources and caused economic burdens and conditions unsuitable for healthy and pleasant living. Proper site design can preserve desirable natural features of the site, minimize expenses for streets and utilities, and provide a safe and pleasant living environment.

Table of Contents

I. Streets

A. Types

1. Collector Streets

2. Local Streets

B. Design Features

1. Emergency Access

2. Cul-de-sacs

3. Intersection Angle

4. Intersection Sight Distance

C. Street Geometry

1. Definitions

2. Design Requirements

D. Construction

II. Walks and Steps

A. Walks

B. Exterior Steps Not Contiguous to Dwelling or Building

1. Flight

2. Risers and Treads

3. Landings

4. Handrails

III. Grading

A. Compaction

B. Gradients

IV. Drainage

A. General

1. Collection and Disposal

2. Concentrated Flow

B. Drainage Design and Flood Hazard Exposure

1. Storm Frequences

2. Street Drainage

3. Foundation Drainage

C. Primary Storm Sewer

1. Pipe Size

2. Minimum Gradient

3. Easements

D. Drainage Swals and Gutters

1. Design

2. Easements

E. Downspouts

1. Outfall

2. Piped Drainage

F. Storm Inlets and Catch Basins

1. Openings

2. Access

G. Drywells

V. Water Supply Systems

A. Individual Water Systems

1. General

2. Well Location

3. Well Construction

4. Pumps and Equipment

5. Storage Tanks

B. Community Water Systems

1. Definition

2. Design

VI. Wastewater Disposal Systems

A. Individual Wastewater Disposal Systems

1. General

2. Percolation Tests

3. Subsurface Absorption Systems

B. Community Wastewater Disposal Systems

1. Definition

2. Design

I. Streets

A. Types -

1. Collector streets. Collector streets are feeder streets which carry traffic from local streets to the major system of arterial streets and highways. They include the principal entrance streets of residential developments and streets for circulation within such developments.

2. Local streets. Local streets are minor streets used primarily for access to abutting properties. These include drives serving multi-family housing units.

B. Design Features -

1. Emergency Access. Access for fire equipment and other emergency vehicles shall be within 100 feet of main building entrances.

2. Cul-de-sacs. Cul-de-sac streets shall have a turn-around with an outside roadway diameter of at least 80 feet, and a right-of-way diameter of at least 100 feet.

3. Intersection Angle. Streets shall be laid out to intersect as nearly as possible at right angles and no street shall intersect any other street at an angle less than 75 degrees. Curb radii shall be a minimum of 20 feet for street intersections.

View Image

4. Intersection Sight Distance. Adequate distances must be maintained at intersections. Vehicles must be visible when within 75 feet of the centerlines of uncontrolled intersecting streets.

C. Street Geometry -1. Definitions. The definitions in Sections I.C.1.a and I.C.1.b. apply to the requirements in Section I.C.2.

a. Terrain Classifications.

(1) Ordinary-Slope less than 8%.

(2) Rolling-Slope range of 8% to 15%.

(3) Hilly-Slope greater than 15%.

b. Development Density (Number of Lots). (Land Area minus Undeveloped Areas greater than Average Lot Size)

(1) Low-Less than 2 lots per acre.

(2) Medium-2 to 6.0 lots per acre.

(3) High-More than six lots per acre.

2. Design Requirements. Collector streets and local streets shall comply with the requirements in tables 1 and 2 unless an exception is granted by the State Director. These requirements may need modification in localities having winter icing conditions.

Table 1-Pavement Widths (feet)

Street typeOn-street parallel parking Development density
Low Medium High
CollectorProhibited263236
CollectorNo Restrictions363640
LocalProhibited181820
LocalPartial, One Side1182026
LocalPartial, One Side1222632
LocalTotal, One Side2222626
LocalTotal, Both Sides2263236

(1) At least one parking space per dwelling is provided off-street.

(2) No parking spaces are provided off-street.

Table 2-Street Design (feet)

Terrain
Ordinary Rolling Hilly
(1) Collector street:
(a) Minimum centerline radius of curvature300225150
(b) Minimum sight distance250200150
(c) Minimum right-of-way width606060
(2) Local Street:
(a) Minimum centerline radius of curvature200150100
(b) Minimum sight distance200150100
(c) Minimum right-of-way width1505050

(1) For cul-de-sac streets, the minimum right-of-way width is 40 feet.

D. Construction. Street configuration and wearing surfaces must provide safe and economical access to all building sites. The design and construction of the street shall be appropriate for all anticipated traffic, climatic and soil conditions. Streets shall meet or exceed all local, county, and State requirements.

II. Walks and Steps

A. Walks. Where walks are provided, they shall be located to assure a minimum vertical clearance of 7 feet from all permanent or temporary obstructions. Walks shall have a slip resistant surface.

B. Exterior Steps Not Contiguous to Dwelling or Building -

1. Flight. a. Single steps or flights of steps exceeding a vertical height of 12 feet shall not be accepted.

b. Steps shall be set back from an intersecting walk or drive a minimum of 1 foot at a retaining wall and 2 feet at slopes.

2. Risers and Treads.

a. Risers shall be a maximum of 6 inches, a minimum of 3 inches and uniform throughout the flight.

b. Treads shall be a minimum of 12 inches and uniform throughout the flight.

c. Treads shall have a slip resistant surface.

d. Treads shall be pitched appropriately to ensure drainage.

3. Landings. a. Minimum length shall equal 3 feet or walk width whichever is greater.

b. A change in direction in a flight of stairs shall be accomplished only at a landing or by a winder which has a tread width at a point 18 inches from the converging end, equal to the full straight stair tread width.

4. Handrails. Stairways having a flight rise exceeding 30 inches shall have a 36 inch high handrail located on one side for stairs 5 feet or less in width and on both sides of stairways over 5 feet wide.

III. Grading

A. Compaction -All fill for street or home construction shall have compaction of not less than 95 percent maximum density, as determined by proctor or other accepted testing methods. Maximum thickness of compaction layers shall be 6 inches except where compaction equipment of demonstrated capability is used under the direction of a qualified soils engineer. Earth fill used to support a building foundation shall be a controlled fill which is designed, supervised, and tested by a qualified soils engineer in accordance with good practice.

B. Gradients. Grading design shall be arranged to assure safe and convenient all-weather pedestrian and vehicular access to residential buildings and to all other necessary site facilities. Site grading shall be designed to establish building floor elevations and ground surface grades which allow drainage of surface water away from buildings and adjacent sites. Grading design shall conform with tables 3 and 4.

Table 3-Access and Parking Gradients1

[In percent]

Minimum Maximum
Center line Crown or cross slope Center line Crown or cross slope
Streets0.51.014.05.0
Street Intersections0.51.025.05.0
Driveways (3).051.014.05.0
Sidewalks (4):
Concrete0.5
Bituminous1.0
Building Entrances & Short Walks1.012.05.0
Main Walks0.510.05.0
Adjoining Steps2.0
Landings1.0
Stepped Ramp Treads1.02.05.0
Parking0.55.05.0

1 Approximate Equivalents .5% = 1/16" ft., 1.0 = 1/8" ft., 2.0% = 1/4" ft., 5.0% = 5/8" ft., 10.0% = 11/4" ft., 12.0% = 11/2" ft., 21% = 25/8" ft.

2 Grades approaching intersections shall not exceed 5 percent for a distance of not less than 100 feet from the centerline of the intersection.

3 Vertical transitions shall percent contact of car undercarriage of bumper with driveway surface.

4 Five percent maximum for major use by elderly tenants.

Table 4-Slope Gradients1

[In percent]

Minimum Maximum
Slope Away From Foundations:
Pervious Surfaces2 5.03 21.0
Impervious Surfaces21.021.0
Pervious Surfaces:
Ground Frost Area2.0
Non-Ground Frost Areas41.0
Impervious Surfaces0.5
Slopes to be maintained by Machine333.0

1 See table 3, footnote (1).

2 Minimum length of 10 feet or as limited by property lines.

3 Minimum length of 4 feet.

4 The minimum is 2.0% if the annual precipitation is more than 50 inches.

IV. Drainage

A. General -

1. Collection and Disposal. Surface and subsurface drainage systems shall be provided, as appropriate, for collection and disposal of storm drainage and subsurface water. These systems shall provide for the safety and convenience of occupants. They shall protect dwellings, other improvements and useable lot areas from water damage, flooding, and erosion.

2. Concentrated Flow. Where storm drainage flow is concentrated, permanently maintained facilities shall be provided to prevent significant erosion and other damage or flooding on site or on adjacent properties.

B. Drainage Design and Flood Hazard Exposure -

1. Storm Frequency. Drainage facilities shall be designed for a 10 year storm frequency of 24-hour duration. Full potential development of all contributing areas shall be used as a basis for this determination.

2. Street Drainage. Streets shall be useable during runoff equivalent to a 10-year return frequency. Where drainage outfall is inadequate to prevent runoff equivalent to a 10-year return frequency from ponding over 6 inches deep, streets shall be made passable for local commonly used emergency vehicles during runoff equivalent to a 25-year return frequency except where an alternative access street not subject to such ponding is available.

3. Foundation Drainage. Appropriate crawl space and foundation drainage shall be provided for the removal of subsurface moisture.

C. Primary Storm Sewer -

1. Pipe Size. Pipe size for the primary storm sewer (any storm sewer or inlet lateral located in a street or other public right-of-way) shall have an inside diameter based on design analysis but not less than 15 inches. Where anticipated runoff from the five-year return frequency rainfall will not fill a 15 inch pipe, a primary storm sewer system usually is unnecessary.

2. Minimum Gradient. Minimum gradient shall be selected to provide for self-scouring of the conduit under low-flow conditions and for removal of sediments foreseeable from the drainage area.

3. Easements. Easements for storm sewers shall be a minimum of 10 feet in width.

D. Drainage Swals and Gutters -

1. Design. Paved gutters shall have a minimum grade of 0.5 percent. Paved gutters and unpaved drainage swales shall have adequate depth and width to accommodate the maximum foreseeable runoff without overflow. Swales and gutters shall be seeded, sodded, sprigged or paved as appropriate to minimize potential erosion. Side slopes shall be no steeper than 2:1.

2. Easements. Surface channels shall have an easement which is at least the width of the channel plus 10 feet.

E. Downspouts -

1. Outfall. Where downspouts are provided, they shall either be connected to an available storm sewer, provided with suitable splash blocks, or empty at acceptable locations onto paved areas so that water drains away from buildings. Downspouts shall not connect to sanitary sewers.

2. Piped Drainage. Piped roof drainage from buildings shall be connected to available storm sewers or empty at locations where no erosion or other damage will be caused.

F. Storm Inlets and Catch Basins -

1. Openings. Where inlets are accessible to small children, openings shall have one dimension limited to 6 inch access. Inlet openings in paved areas shall be designed to avoid entrapment or impedence of bicycles, baby carriages, etc.

2. Access. Access for cleaning shall be provided to all inlet boxes and catch basins.

G. Drywells -Drywells for the disposal of water from foundation drains, crawl spaces, and other small quantity sources shall be permissible where the bottom of drywells project into strata of undistributed porous soil at a level where the bottom of the drywell will be above the ground water table at its highest seasonal elevation.

V. Water Supply Systems

A. Individual Water Systems -

1. General. a. In this subpart, an individual water system is a system which serves fewer customers or connections than the lower threshold for community systems stated in the Safe Drinking Water Act.

b. The system for an individual household should be capable of delivering a sustained flow of 5 gpm. A system supplying water to multiple household shall be designed by a Professional Engineer and have sufficient capacity to serve estimated demand. A test of at least 4 hours duration shall be conducted to determine the yield and maximum drawdown for all wells developed as part of an individual water system. This test may be waived by the State Office based on the hydrologic and geologic conditions in the area.

c. Water that requires continual or repetitive treatment to be safe bacterially is not acceptable.

d. After installation, the system should be disinfected in accordance with the recommendations of the health authority. In the absence of a health authority, system cleaning and disinfection should conform with the current EPA Manual of Individual Water Supply Systems.

e. Any method for individual water supply contained herein which is not permitted by the local health authority having jurisdiction shall not be used.

2. Well Location -

a. A well located within the foundation walls of a dwelling is not acceptable except in arctic and sub-arctic regions.

b. Water which comes from soil formation which may be polluted or contaminated or is fissured or creviced or which is less than 20 feet below the natural ground surface (subject to the requirements of the local health authority) is not acceptable.

c. Individual water supply systems are not acceptable for individual lots in areas where chemical soil poisoning is practiced if the overburden of soil between the ground surface and the water bearing strata is coarse-grained sand, gravel, or porous rock, or is creviced in a manner which will permit the recharge water to carry the toxicants into the zone of saturation.

d. Table 5 shall be used in establishing the minimum acceptable distances between wells and sources of pollution located on either the same or adjoining lots. These distances may be increased by either the health authority having jurisdiction or the FmHA or its successor agency under Public Law 103-354 State Director.

Table 5-Distance From Source of Pollution

Source of pollution Minimum horizontal distance (feet)
Property Line10
Septic Tank50
Absorption field1100
Seepage pit1100
Absorption Bed1100
Sewer Lines w/Permanent Watertight Joints10
Other Sewer Lines50
Chemically Poisoned Soil1100
Dry Well50
Other(2)-

NOTES:

1 The horizontal distance between the sewage absorption system and the well, or the chemically poisoned soil and the well, may be reduced to 50 feet only where the ground surface is effectively separated from the water bearing formation by an extensive, continuous impervious strata of clay, hard-pan, or rock. The well shall be constructed so as to prevent the entrance of surface water and contaminants.

2 Other sources of pollution could be fuel oil or gasoline storage tanks, farm yards or chemical storage tanks, etc. The well should be separated from these sources of pollution a distance recommended by the local health authority.

3. Well Construction -

a. The well shall be constructed to allow the pump to be easily placed and to function properly.

b. All drilled wells shall be provided with a sound, durable and watertight casing capable of sustaining the loads imposed. The casing shall extend from a point several feet below the water level at drawdown or from an impervious strata above the water level, to 12 inches above either the ground surface or the pump room floor. The casing shall be sealed at the upper opening.

c. Bored wells shall be lined with concrete, vitrified clay, or equivalent materials.

d. The space between the casing or liner and the wall of the well hole shall be sealed with cement grout.

e. The well casing shall not be used to convey water except under positive pressure. A separate drop pipe shall be used for suction line.

f. When sand or silt is encountered in the water-bearing formation, the well shall either be gravel packed, or a removable strainer or screen shall be installed.

g. The surface of the ground above and around the well shall be graded to drain surface water away from the well.

h. Openings in the casing, cap, or concrete cover for the entrance of pipes, pump or manholes, shall be made watertight.

i. If a breather is provided, it shall extend above the highest level to which surface water may rise. The breather shall be watertight, and the open end shall be screened and positioned to prevent entry of dust, insects and foregin objects.

4. Pumps and Equipment -

a. Pumps shall be capable of delivering the volume of water required herein under normal operating pressures within the living unit. Well pump capacity shall not exceed the output of the well.

b. Pumps and equipment shall be mounted to be free of objectionable noises, vibrations, flooding, pollution, and freezing.

c. Suction lines shall terminate below maximum drawdown of the water level in the well.

d. Horizontal segments of suction line shall be placed below the frost line in a sealed casing pipe or in at least 4 inches of concrete. The distance from suction line to sources of pollution shall be not less than shown in table 5.

5. Storage Tanks -

a. A system for an individual household shall include a pressure tank having a minimum capacity of 42-gallons. However, prepressured tanks and other pressurizing devices are acceptable provided that delivery between pump cycles equals or exceeds that of a 42 gallon tank. Storage capacity on a system for multiple households must be sufficient to meet estimated peak demands.

b. Tanks shall be equipped with a clean-out plug at the lowest point, and if pressurized, a suitable pressure relief valve.

c. When additional storage is necessary because the well yield will not meet the system peak demands, all nonpressurized intermediate tanks shall be designed and installed in a manner that will prevent the pollution or degradation of the water supply.

B. Community Water Systems -

1. Definition. In this subpart, a community water system is a system which meets the definition in the Safe Drinking Water Act.

2. Design. A community water system shall be designed by a qualified, professional engineer licensed in the state in which the water system will be located. Community water systems shall comply with all Federal and State laws.

VI. Wastewater Disposal Systems

Each dwelling shall be provided with a water-carried system adequate to dispose of domestic wastes in a manner which will not create a nuisance, contaminate any existing or prospective water source or water supply, or in any way endanger the public health.

A. Individual Wastewater Disposal Systems -

1. General. a. In this subpart, an individual wastewater disposal system is a sewage disposal system which serves only 1 dwelling unit.

b. When service from an acceptable public or community system is not available or feasible, and ground water and soil conditions are acceptable, an individual system may be used.

c. Each individual wastewater disposal system shall consist of a house sewer, a pretreatment unit (e.g., septic tank, individual package treatment plant), and acceptable absorption system (subsurface absorption field, seepage pit(s), or subsurface absorption bed). The system shall be designed to receive all sanitary sewage (bathrooms, kitchen and laundry) from the dwelling, but not footing or roof drainage. It shall be designed so that gases generated anywhere in the system can easily flow back to the building sewer stack.

2. Percolation Tests -

a. Percolation tests are required unless a waiver is granted by the National Office. Waivers may be granted on a statewide or local basis in cases where an onsite evaluation of soils would be performed by a qualified soil technician, soil scientist, or engineer. Requests for waivers must describe the qualifications of the person evaluating the soils and discuss the criteria to be used in designing the absorption system.

b. In uniform soils one percolation test shall be made within each area proposed for an absorption system. If significant soil variations are encountered or expected, additional tests shall be made for each variation.

c. Percolation tests shall be conducted in accordance with good practice. Guidance for performing these tests is included in the EPA design manual, "Onsite Wastewater Treatment and Disposal Systems."

3. Subsurface Absorption System -

a. Where percolation rates, soil characteristics and site conditions are acceptable, an absorption system may be installed in an area which is well drained, has an acceptable slope, and is acceptable for excavation.

b. Soils with percolation rates less than 1 minute per inch may be used if the soil is replaced with a layer of loamy or fine sand at least 2 feet thick. (Refer to the EPA Design Manual, "Onsite Wastewater Treatment and Disposal System".)

c. Soils with percolation rates greater than 60 minutes per inch are not acceptable for subsurface wastewater disposal systems.

B. Community Wastewater Disposal Systems -

1. Definition. In this subpart, a community wastewater disposal system is any wastewater disposal system which serves more than 1 dwelling unit.

2. Design. A community wastewater disposal system shall be designed by a qualified, professional engineer licensed in the state in which the system will be located.

7 C.F.R. 1924 app Exhibit B to Subpart C of Part 1924

52 FR 19284, May 22, 1987