47 C.F.R. § 22.759

Current through October 31, 2024
Section 22.759 - Power limit for BETRS

The effective radiated power of central office and rural subscriber station transmitters used in basic exchange telephone radio systems must not exceed the limits in this section.

(a)Maximum ERP. The effective radiated power (ERP) of central office and rural subscriber station transmitters in BETRS must not exceed the applicable limits in this paragraph under any circumstances.

Frequency range (MHz) Maximum ERP (watts)
152-1531400
157-159150
454-4553500
459-460150

(b)Height-power limit. The ERP of central office stations in BETRS must not exceed the amount calculated as follows:

ERPw = 557,418 ÷ hm2

where ERPw is the effective radiated power in Watts

hm is the average (eight cardinal radial) antenna height above average terrain in meters

47 C.F.R. §22.759