40 C.F.R. § 461.53

Current through October 31, 2024
Section 461.53 - New source performance standards (NSPS)
(a) The discharge of wastewater pollutants from any new source subject to this subpart shall not exceed the standards set forth below:
(1) Subpart E-Lead Iodide Cathodes-NSPS.

Pollutant or pollutant propertyMaximum for any 1 dayMaximum for monthly average
Metric units-mg/kg of lead
English units-pounds per 1,000,000 pounds of lead
Chromium23.349.46
Lead17.668.20
Iron75.7038.48
TSS946.2756.96
pH(1)(1)

1 Within the range of 7.5-10.0 at all times.

(2) Subpart E-Iron Disulfide Cathodes-NSPS.

Pollutant or pollutant propertyMaximum for any 1 dayMaximum for monthly average
Metric units-mg/kg of Iron disulfide
English units-pounds per 1,000,000 pounds of Iron disulfide
Chromium2.791.13
Lead2.110.98
Iron9.054.60
TSS113.190.5
pH(1)(1)

1 Within the range of 7.5-10.0 at all times.

(3) Subpart E-Miscellaneous Wastewater Streams-NSPS.

Pollutant or pollutant propertyMaximum for any 1 dayMaximum for monthly average
Metric units-mg/kg of cells produced
English units-pounds per 1,000,000 pounds of cells produced
Chromium0.0390.016
Lead0.0300.014
Iron0.1290.066
TSS1.621.30
pH(1)(1)

1 Within the range of 7.5-10.0 at all times.

(4) Subpart E-Air Scrubbers-NSPS.

Pollutant or pollutant propertyMaximum for any 1 dayMaximum for monthly average
Metric units-mg/kg of cells produced
English units-pounds per 1,000,000 pounds of cells produced
TSS434.0207.0
pH(1)(1)

1 Within the range of 7.5-10.0 at all times.

(b) There shall be no discharge allowance for process wastewater pollutants from any battery manufacturing operation other than those battery manufacturing operations listed above.

40 C.F.R. § 461.53