Section 427.97 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology

The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology.

Effluent characteristicEffluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed-
Metric units (kg/kkg of finished asbestos products)
TSS0.180.09
pH(1)(1)
English units (lb/1,000 lb of finished asbestos products)
TSS0.180.09
pH(1)(1)

1 Within the range 6.0 to 9.0.