30 C.F.R. § 75.1325

Current through October 31, 2024
Section 75.1325 - Firing procedures
(a) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person.
(b) Only one face in a working place shall be blasted at a time, except that when blasting cut coal up to three faces may be blasted in a round if each face has a separate kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit to fire more than 20 boreholes in a round under the provisions of 30 CFR 75.1320 and 75.1321 may not be obtained for use when blasting multiple faces.
(c) Before blasting-
(1) All persons shall leave the blasting area and each immediately adjacent working place where a hazard would be created by the blast, to an area that is around at least one corner from the blasting area;
(2) The qualified person shall ascertain that all persons are a safe distance from the blasting area; and
(3) A warning shall be given and adequate time allowed for persons to respond.
(d) All shots shall be fired promptly, after all persons have been removed to a safe location.

30 C.F.R. §75.1325

35 FR 17890, Nov. 20, 1970, as amended at 56 FR 51616, Oct. 11, 1991